Cookies Policy

The website of the University of Cádiz uses its own and third-party cookies to carry out analysis of use and measurement of traffic, as well as to allow the correct functioning in social networks, and in this way to improve your browsing experience.

If you want to configure cookies, press the button Customize Cookies. You can also access the cookie settings at any time from the corresponding link in the footer.

For more information about cookies you can consult the Cookies policy from the website of the University of Cádiz.

Cookies customization

The website of the University of Cádiz uses its own and third-party cookies to carry out analysis of use and measurement of traffic, as well as to allow the correct functioning in social networks, and in this way to improve your browsing experience.

For more information about cookies you can consult the Cookies policy from the website of the University of Cádiz. You can also access the cookie settings at any time from the corresponding link in the footer.

You can configure the website cookies according to their purpose:

  • Statistical analysis

    Third-party cookies (Google Analytics) are used on this site that allow the number of users to be quantified anonymously (personal data will never be obtained to identify the user) and thus be able to analyze the use made by users of our service, in order to improve the browsing experience and offer our content optimally.

  • Social networks

    Third-party cookies are used on this website that allow the proper functioning of some social networks (mainly YouTube and Twitter) without using any personal data of the user.

UniversidaddeCádiz
Instituto de Lingüística Aplicada - ILA

Eyetracking

 

TOBII PRO 1.200 Hz EYETRACKING EQUIPMENT

 

 

Description:

This equipment is located in the eye recording room at the Experimental Linguistics Unit of the Institute of Applied Linguistics of the University of Cadiz, second floor of the Multipurpose Building, at the Cadiz campus. It consists of Tobii Spectrum 1,200 Hz hardware and Tobii Pro Lab Full Edition software.

Characteristics of the Tobii Pro Spectrum eye tracker system:

1. Collects precise and accurate gaze data.
2. Integrated processing unit.
2.2. The system meets the most stringent demands of studies requiring a high sampling rate; e.g. the need to study eye movements such as microsaccades, saccades, correction saccades, fixations, changes in pupil size and blinks. The high stability of the sampling rate (<0.3% variability) allows precise synchronization of gaze data with data from other sources, e.g. EEG systems (hardware synchronization: the system can send or receive stimuli). The sampling rate is used to detect subtle eye movements, such as microsaccades.

Unique features of the Tobii Pro Lab analysis software package:

The Pro Lab software, suitable for conducting experiments with the Tobii Pro Spectrum eye tracker, has 3 modules for Design, Recording and Analysis of the data obtained and includes, among others, the following unique features:

– Feedback from the researcher to the participant in real time (gaze position available on the secondary monitor) through live viewing functionality.
– Automatic calibration validation for more accurate estimates of data quality after eye tracker calibration
– Dynamic areas of interest (AOIs) tool
– Segment-based analysis for the video stimulus
– Instant access to collected data through visualization tools (e.g., heat maps, gaze streams, etc.) and comprehensive statistics (time to first fixation, fixation duration, etc.)
– Set of saccadic metrics available for exporting saccadic eye movement measurements, such as amplitude, peak velocity, and direction
– Speed and ease of experiment design, analysis and communication of large volumes of data
– Tobii I-VT fixation filter with customizable thresholds and filtering methods
– Noise reduction filter using moving median
– GSR compatibility (Shimmer already integrated)

 

PROCUREMENT REFERENCE (Call and year of acquisition).
Call 2017 for grants for R&D&I infrastructures and equipment (order of April 7, 2017, call 2017) PAIDI. ID Code: 5761. File No.: 1152710. Grant date: 06/11/2019.
Acquisition date: 2021.

 

GENERAL USE PROTOCOL
Request via CAU to the ILA.
Use in the ILA facilities (Eyetracking Laboratory) during the hours established by the center.
Technician required.

 

TYPE OF FEES ACCORDING TO REGULATIONS
A) Fee for internal users of the UCA: 15 €.
B) Rate for external users of public/private organizations with non-profit activity: 19 €.
C) Fee for other external users: 23 €.

 

INFORMATION ABOUT THE INTEREST OF THE INFRASTRUCTURE FOR THE UCA COMMUNITY
This system sets a new standard for remote eye trackers by capturing gaze data at speeds up to 1200 Hz. The Pro Spectrum is extremely accurate with high tracking capability.

 

Coordination: Carmen Varo Varo

 

Location: Experimental Linguistics Unit of the Institute of Applied Linguistics of the University of Cadiz. Second floor of the Multipurpose Building, at the Cadiz campus.

 

Contact: ila@uca.es